logo-orange.png
MCB1
Biaxial stimulation of a cells in a monolayer or 3D matrix

The MCB1 uses a complex deformable interface to generate radial motion patterns on a 24-pin mounting ring.  User-supplied 35mm diameter membranes, scaffolds, and tissues can be puncture-mounted to this ring and biaxially stretched according to the specified protocol.  The entire assembly can be sterilized and is suitable for long-term cell culture in a laboratory incubator.

Key Features

  • Biaxial stretch up to 20%

  • Compatible with a wide range of materials including silicone membranes, decellularized tissues, hydrogels, electrospun materials, and more.

  • PC-independent operation

  • User-friendly interface software for specifying simple, cyclic, and intermittent stimulation protocols for download to the device controller

The MCFX uses a single-use flexible silicone well plate to culture cells in much the same environment as a traditional polystyrene well plate. After allowing the cells to develop adhesion to the well bottom, the MCFX can execute a user-specified stretch protocol to the well plate, causing the cells to deform. The well bottoms have similar optical properties to a glass coverslip, permitting high-magnification imaging of the cultured cells. The well plates can be sterilized and the system is suitable for long-term cell culture in a laboratory incubator.

Key Features

  • Uniaxial stretch of 16 culture wells in a single-use silicone well plate

  • 0.25mm thick membranes for high-magnification imaging using an inverted microscope

  • PC-independent operation

  • User-friendly interface software for specifying simple, cyclic, and intermittent stimulation protocols for download to the device controller

MCFX

High throughput uniaxial stimulation of cell cultures with real-time imaging.

MCT6

High force uniaxial stimulation of 6 parallel specimens

The MCT6 uses a powerful actuator and screw-driven clamp grips to apply user-specified stretch protocols. The systems support specimens up to 10mm wide and 80mm long. The system can also be adapted to wider sheet-like specimens and fiber specimens. The entire assembly can be sterilized and is suitable for long-term cell culture in a laboratory incubator.

Key Features

  • Uniaxial stretch up to 80mm grip separation

  • Compatible with a wide range of materials including silicone membranes, decellularized tissues, hydrogels, electrospun materials, and more.

  • PC-independent operation

  • User-friendly interface software for specifying simple, cyclic, and intermittent stimulation protocols for download to the device controller

Brochure
Our mission is your success!